Everyday tools ↗

Engineering & circuits / FREE BROWSER TOOL

Voltage drop.

Estimate DC or single-phase resistive conductor drop using a supplied resistivity and one-way length.

YOUR EVERYDAY DESKKeep your
next task close.
Switch between tools ↗
Voltage drop
See result ↓● Live result
01 / YOUR INPUTS

Supply the material resistivity at the operating temperature.

Processed on this device.

02 / YOUR RESULT

Your answer

ON YOUR DEVICE

Your result will appear here.

Adjust a field to calculate.

LOCAL INPUTS / CLEAR WORKING / USEFUL OUTPUTNothing to sign in to.

Built and maintained by Operance Labs · Report a calculation or documentation issue

A LITTLE KNOW-HOW

How to use
this tool.

  1. Enter the physical quantities using the units printed beside each field.
  2. Set efficiencies, material properties and allowances from your own measured or manufacturer data.
  3. Review the result breakdown and the stated model assumptions.

What the inputs mean

One-way conductor length (m)
Enter one-way conductor length (m).
Conductor cross-section (mm²)
Enter conductor cross-section (mm²).
Resistivity (Ω·mm²/m)
Supply the material resistivity at the operating temperature.
Current (A)
Enter current (a).
Source voltage (V)
Enter source voltage (v).
Return path
Choose Equal outgoing and return conductors, Single specified conductor only.
A WORKED STARTING POINT

See the working.

Inputs used in this example

These are example values, not a current price, tariff or personal recommendation. Reset example restores them in the workspace.

InputExample value
One-way conductor length (m)10
Conductor cross-section (mm²)2.5
Resistivity (Ω·mm²/m)0.0175
Current (A)10
Source voltage (V)230
Return pathEqual outgoing and return conductors

Resistive voltage drop

1.4 V

R = resistivity × total path length ÷ cross-section; ΔV = I × R

  • Drop: 0.608696%; load voltage: 228.6 V; cable loss: 14 W.
  • Ignores inductive reactance, skin effect and connections. This is not conductor ampacity or wiring-code sizing.

Estimate DC or single-phase resistive conductor drop using a supplied resistivity and one-way length.

Idealized calculations do not select equipment ratings or certify a physical installation.

Your inputs stay here

Your input is processed on this device. PixelDesk does not upload it to a calculation or file-processing server. Copying and downloading are deliberate actions. Closing the page clears the in-memory inputs; the app remembers only its theme and public reference-rate cache.

Methods and public data ↗

Keep a useful
thing close.

All engineering & circuits ↗

Questions, answered.

What can I do with voltage drop?

Estimate DC or single-phase resistive conductor drop using a supplied resistivity and one-way length.

What does the voltage drop example show?

With One-way conductor length (m): 10; Conductor cross-section (mm²): 2.5; Resistivity (Ω·mm²/m): 0.0175, the example returns 1.4 V. The workspace shows the substituted formula and its assumptions; Reset example restores these inputs.

What should I check before using the result?

Estimate DC or single-phase resistive conductor drop using a supplied resistivity and one-way length.