A WORKED STARTING POINTSee the working.
Inputs used in this example
These are example values, not a current price, tariff or personal recommendation. Reset example restores them in the workspace.
| Input | Example value |
|---|
| Water volume (L) | 100 |
|---|
| Starting water temperature (°C) | 10 |
|---|
| Target water temperature (°C) | 60 |
|---|
| Water density (kg/L) | 0.998 |
|---|
| Specific heat capacity (kJ/kg·K) | 4.186 |
|---|
| Heat-delivery efficiency (%) | 90 |
|---|
| Heater input power (kW) | 3 |
|---|
| Energy price per input kWh | 0.2 |
|---|
Estimated heater input energy
6.44695679 kWhuseful kWh = litres × kg/L × kJ/(kg·K) × ΔT ÷ 3,600; input = useful kWh ÷ efficiency
- Useful sensible heat: 5.802261 kWh; heating time at constant input power: 2.148986 h; cost: 1.289391.
- Liquid-water model from 0–100 °C only; no boiling, freezing, tank warm-up, evaporative loss or ongoing storage/piping losses.
Estimate sensible heat energy, input energy and heating time for liquid water without phase change.
Scenario estimates use your supplied prices, efficiencies and conditions.
Your inputs stay here
Your input is processed on this device. PixelDesk does not upload it to a calculation or file-processing server. Copying and downloading are deliberate actions. Closing the page clears the in-memory inputs; the app remembers only its theme and public reference-rate cache.
Methods and public data ↗